Specifications:
Voltage: DC 5V~36V.
Trigger Signal Source: High voltage level trigger (3. 0V~24V), signal ground and system ground are not on common ground to improve the system’s anti-jamming capability (you can also connect them on common ground).
Output Capacity: DC 5V~36V, at room temperature, continuous current is 15A, power 400W. With enhanced heat dissipation, the current can be up to 30A.
Quiescent Current: 20mA
Operating Current: 50mA
Working Temperature: -40℃~85℃
Clocking (Time Delay) Range: 0.1seconds to 999minutes
Size: 60*34*12mm / 2. 36*1. 33*0.47inch
Instruction:
Operating Mode:
P1: trigger signal, the relay is on “OP” time, and then disconnect; in the “OP” time, as follows:
P1. 1: signal is triggered again, invalid
P1. 2: signal is triggered again, the clocking is reset
P1. 3: Signal is trigger again reset, relay off, and stop the clocking;
P-2: trigger signal, the relay off “CL” of time, the relay on “OP” time, and then disconnect relay after clocking;
P3. 1: trigger signal, the relay is turned on after the “OP” time, the relay off “CL” time, then the operation cycles; if trigger signal again during the cycle, the relay off, stop clocking; the number of cycles times ( “LOP “) can be set.
Note:
1. The module is an active output, the output voltage equal to the input voltage.
2. ‘DC + ‘and’ load + ‘ are internally shorted(connected), but’ DC- ‘and’ load – ‘ cannot be shorted, otherwise the load cannot be controlled on and off, which is equivalent to load being powered on always.
Package Includes:
1 x Timer Switch Module