Key points:
The high level time of the output of this product is adjustable, 2.5 seconds to 1 hour.
Refer to the relevant form below.
Blocking time, 2 seconds, not adjustable.
The factory is defined as repeatable trigger and cannot be changed.
The supply voltage of this module is 3.3V to 15V, and the limit voltage is 2.8V to 18V.
Module output timing is: output high level for 2 seconds after power-on, then go low, enter standby
status. If the delay time is changed, the time when the module outputs a high level after power-on will increase accordingly, which can be understood as The startup time after entering the normal working state after the electric power will increase.
After installing the photosensitive element, it does not work during the day, work at night, does not contain photosensitive components, and works all day ( There are no photodiodes on the module,please purchase separately if needed. Recommended: ordinary F3 photodiode )
Package include:
5 x Module